Preparing electrical installation
6.5.1
SELV supply voltage
For commissioning and operation of the LMS5xx, you need:
•
LMS5xx: SELV supply voltage DC 19.2 to 28.8 V according to IEC 60364441
More data
see "Mechanics/electronics", page 88
.
WARNING
Risk of injury due to electric current!
If the supply voltage is produced by a power supply unit, then insufficient electrical
separation between input and output current circuit of the power supply unit may lead
to an electric shock.
■
Only use a power supply unit whose output circuit has safe electrical separation
from the input circuit. For example with a safety transformer in accordance with
EN 61558-1.
6.5.2
LMS500 Indoor cable cross-section
The Indoor devices have screw terminals which are connected with the following wire
cross-sections:
Table 37: Specification of the wire cross-sections for the screw terminals of the LMS500
Lite/PRO Indoor
Cable type
Minimum cross-section
Maximum cross-section
Flexible conductor (fine
multi-stranded wire)
0.14 mm²
1 mm²
Rigid strands (one wire)
0.14 mm²
1.5 mm²
Flexible conductor (fine multi-
stranded wire) with ferrules
0.25 mm²
0.5 mm²
Wire cross-section
•
All connections must be wired with copper cables.
•
All communication cables must be stranded and shielded.
•
For the cable calculation
see "Example of maximum cable connection", page 66