LMS511 PRO, LMS581 PRO and LMS511 Heavy Duty Outdoor: "I/O” connection
Table 28: LMS511 PRO, LMS581 PRO and LMS511 Heavy Duty Outdoor: Pin assignment of “I/O” connection
Male/female connector
Contact
Short form
Signal description
Wire colors connect‐
ing cable part no.
6042732
1.
3
1
7
2
6
5
4
8
9
10
12
11
Figure 46: M12 female con‐
nector, 12-pin, A-coded
1
V
S
OUT
Supply voltage of digital out‐
puts 3 ... 6
Brown
2
GND IN1/2
Ground for digital inputs 1
and 2
Blue
3
IN1
Digital input 1
White
4
GND IN3/4/IN Sync
Ground for digital inputs
3 and 4 / Synchronization
input
Green
5
IN2
Digital input 2
Pink
6
IN3
Digital input 3
Yellow
7
GND OUT 3 ... 6
Supply voltage ground of dig‐
ital outputs 3... 6
Black
8
IN4/IN Sync
Digital input 4 / Synchroniza‐
tion input
Gray
9
OUT3
Digital output 3
Red
10
OUT4
Digital output 4
Violet
11
OUT5
Digital output 5
Gray+pink
12
OUT6/OUT Sync
Digital output 6 / Synchroni‐
zation output
Red+blue
1.
Example values when using the specified connecting cable(s). Signal assignment and wire colors can vary when using other connecting
cables.
6.4.3
Connections of the LMS531 Security Outdoor
Connections of the LMS531 Security Outdoor LMS531 Lite and PRO Security Outdoor: “Power” connection
Table 29: LMS531 Lite Security Outdoor: Pin assignment of the “Power” connection
Male/female connec‐
tor
Contact
Short form
Signal description
Wire colors connect‐
ing cable part no.
6036159
1.
1
4
3
5
2
Figure 47: M12 male
connector, 5-pin, A-
coded
1
V
S
Sensor supply voltage
Brown
2
V
S
heat.
Heating supply voltage
White
3
GND
Ground sensor
Blue
4
Reserved
Do not use!
–
5
GND heat.
Ground heating
Black
1.
Example values when using the specified connecting cable(s). Signal assignment and wire colors can vary when using other connecting
cables.
Required minimum voltage at flying leads for part no. 6036159: 20.3 V
ELECTRICAL INSTALLATION
6
8013796/1ALS/2021-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | LMS5xx
61
Subject to change without notice