Echo
c
Interlaced mode,
note: Particle filter
must be deactivated
Measuring
core
Fog filter
Average filter
Echo filter
c
All echoes
c
First echo
c
Last echo
Measurement data output
via telegram
SOPAS Scan View Pro
SOPAS field
evaluation monitor
Output signal
switching device
Particle filter
(1 scan delay)
1
Field evaluation
(only one echo;
for “all”, last echo)
1
Note: For interlaced scan configuration, the particle filter must be deactivated.
3.7.1.4.1
Fog filter
The fog filter enables the device to eliminate unwanted echoes at close range. This
considerably lowers the probability of false activations at close range in fog.
Figure 17: Without the fog filter: objects are
difficult to detect through the fog due to reflec‐
tions.
Figure 18: Using the fog filter: objects can be
detected reliably because unwanted echoes
are screened out.
3.7.1.4.2
Echo filter
The echo filter screens out unwanted measurement data and signals caused by edge
hits, rain, dust, snow and other ambient conditions.
You can set whether the first, the last, or all five echoes are output.
The other pulses triggered by undesirable ambient conditions are not taken into
account.
Echo 1
Echo 2
Figure 19: All echos: The device receives unwanted echoes from ambient conditions such as
rain.
PRODUCT DESCRIPTION
3
8013796/1ALS/2021-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | LMS5xx
31
Subject to change without notice