NOTE
The scan data displayed in the scan data monitor and the field evaluation monitor is
already corrected with the scaling factor.
In the case of the
LFEperpdistresult
telegram, the output distance value corresponds
to the actual distance and does not need to be corrected (see telegram listing no.
8014631 under
).
The following tables provide an overview of the possible configurations.
Table 9: Possible configurations of the LMS5xx Lite
Scanning frequency
Angular resolution
Scaling factor for data out‐
put
Max. scanning
range
Interlaced
25 Hz
0.25°
x 2
80 m
-
35 Hz
0.5°
x 2
80 m
-
50 Hz
0.5°
x 2
80 m
-
75 Hz
0.5°
x 1
65 m
-
75 Hz
1°
x 2
80 m
-
Table 10: Possible configurations for LMS5xx PRO/Heavy Duty
Scan‐
ning fre‐
quency
Angular resolution
Scaling
factor
for data
output
Max.
scanning
range
Inter‐
laced
25 Hz
0.042°
x 1
65 m
4-fold
0.1667°
25 Hz
0.083°
x 1
65 m
2-fold
0.1667°
25 Hz
0.1667°
x 1
65 m
-
25 Hz
0.25°
x 2
80 m
-
35 Hz
0.25°
x 1
65 m
-
35 Hz
0.5°
x 2
80 m
-
50 Hz
0.1667°
x 1
65 m
2-fold
0.33°
50 Hz
0.33°
x 1
65 m
-
50 Hz
0.5°
x 2
80 m
-
75 Hz
0.25°
x 1
65 m
2-fold
0.5°
75 Hz
0.5°
x 1
65 m
-
75 Hz
1°
x 2
80 m
-
100 Hz
0.1667°
x 1
65 m
4-fold
0.667°
100 Hz
0.33°
x 1
65 m
2-fold
0.667°
100 Hz
0.5°
x 2
80 m
2-fold 1°
100 Hz
0.667°
x 1
65 m
-
100 Hz
1°
x 2
80 m
-
SOPAS:
Project tree
,
LMS…
,
Parameters
,
Basic Parameters
,
Current Configuration
and
New
Configuration
sections.
3
PRODUCT DESCRIPTION
28
O P E R A T I N G I N S T R U C T I O N S | LMS5xx
8013796/1ALS/2021-03 | SICK
Subject to change without notice