LMS500
LMS511
LMS531
Weight
3.7 kg
Dimensions
160 mm x 155 mm x 185 mm
10.5
Ambient data
LMS500
LMS511
LMS531
Radiance factor
2% ... > 1,000% (reflectors
1.
)
Electromagnetic compatibility
(EMC)
1.
Radiation emitted:
IEC 61000-6-3:2020 / EN 61000-6-3:2007+A1:2011
Electromagnetic immunity: IEC 61000-6-2:2016 / EN IEC
61000-6-2:2019
Chemical resistance
Salt spray test according to DIN EN ISO 9227 NSS:
2006-10-01 test duration: 240 h, test temperature: 35 °C,
5% NaCl solution
Kesternich test according to DIN EN ISO 6988: 1997-3 - KFW
0.2 S test cycle duration: 24 h, number of cycles: 5, concen‐
tration: 0.067% SO2
Vibration resistance
According to IEC 60068-2-6 (2007-12) 10 Hz ... 150 Hz: ampli‐
tude 0.35 mm to 5 g, 20 cycles
Shock resistance
Single shock according to IEC 60068-2-27 (2008-02) 15 g,
11 ms, 6 shocks per axis continuous shock according to IEC
60068-2-27 (2008-02) 10 g, 16 ms, 1,000 shocks per axis
Impact resistance
IK05, IK06, IK07 according to DIN EN 50102-09.1997
Ambient operating tempera‐
ture
0 °C ... +50 °C
Lite/PRO
: -30 °C ... +50 °C
Without heating, at switch-on: 0 °C ...
+50 °C
Without heating, during operation:
-10 °C ... +50 °C
3.
Heavy Duty
: -40 °C ... +60 °C
Without heating, at switch-on: 0 °C ...
+60 °C
Without heating, during operation:
-10 °C ... +60 °C
3.
Storage temperature
–40 °C ... +70 °C (max. 24 h)
Relative humidity
Max. 95%, non-condensing according to DIN EN 60068-2-61,
method 1
Ambient light immunity
70 klx
1.
Corresponds to Diamond Grade 3000X™ (approx. 1,250 cd/lx × m²)
2.
This specification applies to all devices with hardware version II.
For all devices with hardware version I or an unspecified hardware version, the following applies:
•
Radiation emitted: EN 61000-6-4:2007+A1:2011, IEC 61000-6-4:2018 / EN IEC 61000-6-4:2019
•
Electromagnetic immunity: EN 61000-6-2:2005+AC:2005,
IEC 61000-6-2:2016 / EN IEC 61000-6-2:2019
The hardware version of device can be found on the type designation label
3.
When operating the device without heating, a warning message may occur due to no voltage supply for
the heating being connected.
TECHNICAL DATA
10
8013796/1ALS/2021-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | LMS5xx
89
Subject to change without notice