ASSEMBLY AND INSTALLATION
3.2.3
Fitting the optional external purge air unit
Consider the following points when selecting the assembly location:
▸
Install the purge air unit at a location with clean air whenever possible. The air intake
temperature must correspond to specifications in the Technical data (
). In unfavorable conditions, lay an air intake hose or pipe to a location
with better conditions.
▸
The fitting location must be easily accessible and meet all safety regulations.
▸
Install the purge air unit only as far as necessary below the flange with tube for the
sender/receiver unit and reflector/scattered light receiver so that the purge air hoses
can be laid downwards (avoids water collecting).
▸
Provide sufficient clearance to exchange the filter element.
▸
Provide sufficient space to attach and remove the weatherproof cover when installing
the purge air unit outdoors