8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 63
Operating instructions Distance measuring device DL100 Pro – RS-422
Operation via Ethernet (Ethernet interface)
Field "MF1, Function configuration"
Requirements for the display
• Parameter "MF1 activation": Option "On"
Parameter
Description
Function
Select function for multifunction input and output MF1.
Read/Write access
• Read and write
Input value
• 0: Distance:
→
See page 63, field "MF1, Threshold
distance underfloe"
• 1: Velocity:
→
See page 64, field "MF1, Threshold velocity
exceeded"
• 2: Service:
→
See page 65, field "MF1, Service
configuration"
• 3: Laser
• 4: Preset
Factory setting
• Distance
Active state
Select level for the active condition for the multifunction input
and output MF1.
Read/Write access
• Read and write
Input value
• 0: high / 1: low
Factory setting
• Low
Table 35:
Page "Parameter settings" – field "MF1, Function configuration"
Field "MF1, Threshold
distance underflow"
Requirements for the display
• Parameter "MF1 activation": Option "On"
• Parameter "Function": Option "Distance"
Parameter
Description
Threshold
distance
Enter switching threshold for the multifunction output MF1.
Read/Write access
• Read and write
Input value
• –300000 ... 300000
Unit
• mm
Factory setting
• 1990