Operating instructions Distance measuring device DL100 Pro – RS-422
RS-422 interface
72
© SICK AG • Subject to change without notice • 8014753/ZVZ7/2018-03-22
Continuous output
distance value on –
CRLF protocol
Description
Protocol setup
To the DL100
<STX>052201<ETX>
From the DL100
<STX>852201<ETX>
Then continuous output
from the DL100
<[sign]><7*[0...9]><CR><LF>
Example: 5,378.8mm
+00053788<CR><LF>
Continuous output
distance value stop –
SerialLink-Protokoll
Description
Protocol setup
To the DL100
<STX>052200<ETX>
From the DL100: OK
<STX>852200<ETX>
Continuous output
distance value stop –
SerialLink protocol
Description
Protocol setup
To the DL100
<STX>052200<ETX>
From the DL100: OK
<STX>852200<ETX>
Continuous output
deactivation
Description
Protocol setup
To the DL100
<STX>023000<ETX>
From the DL100: OK
<STX>823000<ETX>
Continuous output distance value
and speed value activation
Description
Protocol setup
To the DL100
<STX>023001<ETX>
From the DL100: OK
<STX>823000<ETX>
Continuous output distance value
and status word activation
Description
Protocol setup
To the DL100
<STX>023002<ETX>
From the DL100: OK
<STX>823000<ETX>
10.3.3 Interface function
Select SerialLink protocol
Description
Protocol setup
To the DL100
<STX>023100<ETX>
From the DL100: OK
<STX>823100<ETX>
Select CRLF protocol
Description
Protocol setup
To the DL100
<STX>023101<ETX>
From the DL100: OK
<STX>823100<ETX>