8.5.10 Submenu "MF1 – Speed"
This submenu is used to parameterize the multifunction output MF1 as
speed output.
You can get to the menu "Speed" via the menu path:
Main menu
→
→
Menu
→
→
RS422
→
→
more
→
→
MFx On
→
→
MF1
→
→
Actsta
→
→
Functn
→
→
Speed
Push the
key for at least 2 seconds to get to the "Menu".
Requirements for the display
• Menu "more": Option "On"
• Menu "MFx On": Option "Enable"
• Parameter "Functn": Option "Speed"
Parameter
Description
Limit
Set speed for the switching threshold The switching output is
activated when the current speed exceeds the set speed. The
switching hysteresis is set firmly to ± 0.1m/s.
Adjustment range
Range 0.0 … 9.9 m/s
Factory setting
• 0 [mm]
Sign
Choose the travel direction to be monitored.
Options
•
+ / –: Once the set speed is exceeded in one direction, the
switching output is activated.
•
+: Once the set speed is exceeded with increasing distance,
the switching output is activated.
• –: Once the set speed is exceeded with decreasing distance,
the switching output is activated.
Factory setting
•
+ / –
Table 15: Submenu "MF1 – Speed"