Operating instructions Distance measuring device DL100 Pro – RS-422
Operation via Ethernet (Ethernet interface)
62
© SICK AG • Subject to change without notice • 8014753/ZVZ7/2018-03-22
Field "RS422 configuration“
Parameter
Description
Baud rate
Select Baud rate for interface "RS422".
Read/Write access
• Read and write
Input value
• 0: 115.2 kBaud/ 1: 38.4 kBaud/ 2: 19.2 kBaud /
3: 9600 Baud / 4: 4800
Factory setting
• 115k2
Data format
Select file format for interface "RS422".
→
Also see page 69, chapter 10.2.
Read/Write access
• Read and write
Input value
• 0: 8, n, 1 / 1: 8, e, 1 / 2: 8, o, 1 / 3: 7, n, 1 / 4: 7, e,
1 / 5: 7, o, 1
Factory setting
• 8n1
Output
Select measurement value for interface "RS422".
Read/Write access
• Read and write
Input value
•
0: Request / 1: Distance (cont.) / 2: Di
speed (cont.) / 3: Di speed (cont.)
Factory setting
• Requirement
Protocol
Select protocol type for interface "RS422".
Read/Write access
• Read and write
Input value
• 0: Standard / 1: CR/LF
Factory setting
• CR/LF
Table 33:
Page "Parameter settings" – field "RS422 configuration"
Field "MF1/MF2 activation"
Parameter
Description
MF activation
Activate and deactivate multifunction input and output MF1
and multifunction output MF2.
Read/Write access
• Read and write
Input value
•
0: off / 1: on
Factory setting
• On
Table 34:
Page "Parameter settings" – field "MF1/MF2 activation"