8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 71
Operating instructions Distance measuring device DL100 Pro – RS-422
RS-422 interface
Innentemperatur
Description
Protocol setup
To the DL100
<STX>0126<ETX>
From the DL100
<STX>8126<[sign]><3*[0...9]><ETX>
Example: +45°C
<STX>8126+45<ETX>
Example: –10°C
<STX>8126–10<ETX
Service status word
• Status word is Hex-coded
Description
Protocol setup
To the DL100
<STX>0125<ETX>
From the DL100
<STX>8125<4*[0...F]><ETX>
Bit
Description
0 (LSB)
Warnings
Laser pre-failurel
1
Temperature pre-failure
2
Contamination pre-failure
3
Plausibility
4
Error
Laser
5
Temperature
6
Contamination
7
Plausibility
8
Service
Status MF1, active condition
9
Status MF2, active condition
10
Laser Status on/off
11
Heating status on/off
12 ... 15
Not
assigned
–
10.3.2 Continuous measured value output
Continuous output
distance value on –
SerialLink protocol
Description
Protocol setup
To the DL100
<STX>052201<ETX>
From the DL100
<STX>852201<ETX>
Then continuous output
from the DL100
<STX>0322<[sign]><7*[0...9]><ETX>
Example: 5,378.8 mm
<STX>0322+0053788<ETX>