Operating instructions Distance measuring device DL100 Pro – RS-422
RS-422 interface
74
© SICK AG • Subject to change without notice • 8014753/ZVZ7/2018-03-22
Adjust resolution 100 mm
Description
Protocol setup
To the DL100
<STX>022E04<ETX>
From the DL100: OK
<STX>822E00<ETX>
10.3.5 Special functions
Laser off
Description
Protocol setup
To the DL100
<STX>0333<ETX>
From the DL100: OK
<STX>043300<ETX>
Laser on
Description
Protocol setup
To the DL100
<STX>0332<ETX>
From the DL100: OK
<STX>043200<ETX>
Preset activation
Description
Protocol setup
To the DL100
<STX>0335<ETX>
From the DL100: OK
<STX>043500<ETX>
Permanently store parameter
Description
Protocol setup
To the DL100
<STX>0306<ETX>
From the DL100: OK
<STX>04060001<ETX>
Re-initialization (cold start)
Description
Protocol setup
To the DL100
<STX>030A<ETX>
From the DL100: OK
<STX>040A00<ETX>
Firmware version
reading application processor
Description
Protocol setup
To the DL100
<STX>0118<ETX>
From the DL100: OK
<STX>8118<12*[0...Z + .]<ETX>
Firmware version
reading interface processor
Description
Protocol setup
To the DL100
<STX>0119<ETX>
From the DL100: OK
<STX>8119<12*[0...Z + .]<ETX>
Example:
<STX>8118V001.002.001<ETX>