8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 67
Operating instructions Distance measuring device DL100 Pro – RS-422
Operation via Ethernet (Ethernet interface)
Field "Advanced device function"
(continued)
Parameter
Description
Error rejection
Select time for error suppression. If there is an error, the
measurement value is indicated as "0".
Read/Write access
• Read and write
Input value
•
0: off / 1: 50 ms / 2: 200 ms
Factory setting
• 200 ms
Table 41:
Page "Parameter settings" – field "Advanced device function"
Field "Heater"
Requirements for the display
• Devices with the option "Heating" (DL100-xxHxxxxx)
Parameter
Description
Switching
threshold
Enter power up threshold for heating.
Read/Write access
• Read and write
Input value
•
–10 ... +40
Unit
• °C
Factory setting
• –10
Table 42:
Page "Parameter settings" – field "Heater"
Field "Frequency"
Requirements for the display
• Devices with the option "Frequency" (DL100-xxxBxxxx)
Parameter
Description
Frequency set
Select frequency range.
Read/Write access
• Read and write
Input value
• 0: Mode 1 / 1: Mode 2 / 2: Mode 3 / 3: Mode 4
Unit
• °C
Factory setting
• –10
Table 43:
Page "Parameter settings" – field "Frequency"