82
S 63 E - S 63 E C
Operator's Manual
CAUTION
Any operations for hooking up to the workshop electrical board must be carried out
only by qualified technicians in compliance with the regulations in force, under the
responsibility and at the charge of the customer.
- The electric hook-up must be performed according to:
• absorbed power specifications indicated on the machine dataplate.
• the distance between the machine and the electric hook-up point, so that voltage
drops under full load do not exceed 4% (10% when starting up) of the rated voltage
specified on the data plate.
- The user must:
• fit a plug that respects the current regulations onto the power supply cable;
• connect the machine to its own electrical connection fitted with a suitable 30-mA cur-
rent sensitive circuit breaker;
• fit power supply protection fuses sized in compliance with specifications in the main
wiring diagram of this manual;
• provide the workshop electric installation with an efficient grounding circuit.
- prevent unauthorised use of the machine, always disconnect the power supply plug
when the machine is not used (switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main electrical
board and without the use of a plug, install a key-operated switch or suitable lock-out
device to restrict machine use exclusively to qualified personnel.
CAUTION
For the machine correct functioning it is vital to have a good ground connection. NEVER
connect the machine ground wire to a gas pipe, water pipe, telephone cable or any
other unsuitable object.
COMPRESSED AIR HOOK-UP
CAUTION
All compressed air hook-ups must be carried out by qualified personnel only.
- The hook-up to the workshop's pneumatic system must ensure a minimum pressure of
7 bar (100 psi). Lower pressure levels may prevent the machine's AUTOMATIC WHEEL
LOCKING SYSTEM C from working properly.
- A universal union is used for connection to the compressed air system. No special or
additional adaptor is needed for connection. A pressure-resistant hose with 6mm inner
Summary of Contents for S 63 E
Page 71: ...Manuale d uso S 63 E S 63 E C 71 SCHEMA PNEUMATICO Alimentazione Aria 7 10 bar 100 145 psi ...
Page 89: ...Operator s Manual S 63 E S 63 E C 89 9b DISPLAY PANEL ...
Page 140: ...140 S 63 E S 63 E C Operator s Manual PNEUMATIC DIAGRAM Air supply 7 10 bar 100 145 psi ...
Page 158: ...158 S 63 E S 63 E C Manuel d utilisation 9b PANNEAU D AFFICHAGE ...
Page 227: ...Benutzerhandbuch S 63 E S 63 E C 227 9b ANZEIGEFELD ...
Page 281: ...Benutzerhandbuch S 63 E S 63 E C 281 PNEUMATIKSCHEMA Luftversorgung 7 10 bar 100 145 psi ...
Page 299: ...Manual de uso S 63 E S 63 E C 299 9b PANEL VISOR ...
Page 352: ...352 S 63 E S 63 E C Manual de uso ESQUEMA NEUMÁTICO Alimentación Aire 7 10 bar 100 145 psi ...
Page 353: ...S 63 E S 63 E C 353 Note ...
Page 354: ...354 S 63 E S 63 E C Note ...