55(62)
Note
:
Don't make sundries fall into the barrel, when taking out
the air filter.
6.5.1 The Useful Life of the Key Parts of the Product
Table 6-1
:
The useful life of the key parts of the product
Name of the parts
Useful life
Blower
Above 5 years
Process heater
Above 1 year
Regen. heater
Above 1 year
Contactor
Above 2000,000 act
Honeycomb
5 years
6.6 Cooler Clear Step
1) Disassemble the cooler's pipe and screw, and remove the cooler out of the
chiller.
2) Release the fixed screw on the upper and lower cover of cooler and
disassemble the cover.
3) Use brushes, compressed air or low pressure water to clean the dust and
sundries on the cooler fan and copper pipe. Notes: water residue on the
cooler fan and copper pipe should be dried with compressed air.
4) Make the cooler's upper and lower cover junction clean enough
and smear the silica gel then fixed the covers with screws.
5) Put the cooler on the air at least 4 hours to make the silica gel drying
enough then fix the cooler on the chiller and connect all pipes.