38(62)
4.14.9 Operation process
P
Heat the proportional band
Range:1-100
℃
Default value:40
℃
I
Integral
Range:0-999S
Default
value:120S
D
Differential
Range:0-999S
Default value:20S
OTP
Over temp.
protection temp.(SV+F-05)
Range:2-50
℃
Default value:15
℃
100C
HCLE
Heating switching
cycle
Range:15-60S
Default value:15S
OFF1
Mon. off time
00:00=OFF
OFF2
Tue.off time
00:00=OFF
OFF3
Wed.off
time
00:00=OFF
OFF4
Thu.off time
00:00=OFF
OFF5
Fri.off time
00:00=OFF
OFF6
Sat.off time
00:00=OFF
OFF7
Sun.off time
00:00=OFF
ON 1
Mon. on
time
00:00=OFF
ON 2
Tue.on time
00:00=OFF
ON 3
Wed.on time
00:00=OFF
ON 4
Thu.on time
00:00=OFF
ON 5
Fri.on time
00:00=OFF
ON 6
Sat.on time
00:00=OFF
ON 7
Sun.on time
00:00=OFF
TIME
Now the time
(hour
,
minute)
RON
Intermittent
operation
ON time
Range: 30-600 (Min)
Default value:30
ROFF
Intermittent
operation
OFF time
Range:0
–
600(Min)
Default value:0
RONE
Run time of
intermittent operation
Range:30-600(Min)
Default value:90
UNIT
Temp.unit
Range:
℃
-
℉
Default value:
℃
AUTO
Timing switch
machine function
Range:AUTO-OFF
Default value:OFF
WEEK
Now the time
(week)
FDLY
Windmills delay closing time
Range:30-360S
Default value:180S
LOCK
SV set lock
Range: YES
–
NO
Default value:NO
PRO
communication
protocol
Range:
MODBUS-RTU
ID
CommunicationID
Range:1-99
Default value:1
BAUD
Baud rate
Range:4.8K 9.6K 19.2K
Default value:9.6K
PAR
Parity bit
Range:NONE
,
Odd
,
Even
Default value:Odd
Data
Date length
Range:8bit
Default value: 8bit
Stop
Stop bit
Range: 1bit
,
2bit
Default value: 1bit
M+
△
+3S
SV
Range:0-200
℃
Default value:90
℃
100C
M+2S
M+5S
M+
▽
+3S
M+7S
△
/
▽
△
/
▽
△
/
▽
△
/
▽
△
/
▽
M leave
M express
:
Menu key
△
/
▽
express
:
Up/Down key
Summary of Contents for SCD-160Ux2/200H
Page 1: ...SCD One to Two Compact Dryer Date Aug 2018 Version Ver A English ...
Page 2: ......