25(62)
4. Application and Operation
Turn on the main switch to connect power supply on the control panel.
4.1 Dehumidifying System Operation
1) Open the main switch.
2) Press "RUN/STOP "key to start dehumidifying working.
4.2 Temperature Setup
1) The setup number will flicker after pressing "SET" key, add or decrease
temperature by pressing
key.
2) Press "ENTER" key to confirm the input value.
4.3 PID Auto-tuning Setting
1) Press
“
SET
”
and the digits flash. At this time press
“
SET
”
and
”
Enter
”
meanwhile for 1.5 seconds to enter auto-tuning mode. Then two values of
“
At
”
and
“
Present temperature
”
will display alternatively in PV and the set
temperature value displays in SV till auto-tuning is finished. After that,
system goes back to the normal operation directly.
2) If auto-tuning setting could not be finished within 1 hour, the parameters
will not be altered and system goes back to normal operation.
3) Pressing
“
ON/OFF
”
to go back normal operation amid automatic
calculation would not alter the original parameters.
Note: Before delivery, PID parameter has been already set. Don
’
t
process the PID auto-turing function unless it is necessary.
4.4 Intermittent Running Setup
Drying periods(0-ON)
Stop periods (0-OFF)
1) Press
“
SET
”
key to enter setting mode, press
“
TEMP/TIMER
”
key , the
temperature set value switches to time set value. In this time,
“
SV/set
value
”
flickers, and
“
PV/ set value
”
displays
“
0-ON
”
.
→
←
Summary of Contents for SCD-160Ux2/200H