31(62)
2) F-40 is to set low-temp. alarm, press
key to modify the value of
low-temp. alarm.
3) After the setting, press
“
ENTER
”
key to confirm, press
“
SET
”
key, do not
save the value then exit.
4) The default value is 20 .
℃
4.10.2 Reaction Time of Low-temp. Alarm
1) After F-40 setting is finished, press
“
ENTER
”
key, at this time, PV displays
F-41.
Picture 4-13: Reaction Time of Low-temp. Alarm
2) F-41 is the reaction time of low-temp. alarm, press
key to modify
the reaction time and start it. When the reaction time is OFF, low-temp.
alarm function is closed.
3) The default value is OFF.
4.11
Heater Alarm
1) After F-41 setting is finished, press
“
ENTER
”
key, at this time, PV displays
F-42.
Picture 4-14: Heater Alarm
2) F-42 is heater alarm, press
key to modify the alarm time and start it.
When heater alarm is OFF, heater alarm function is closed. When it works,
if the heater doesn
’
t below the set temperature minus 5 within ala
℃
rm set