35(62)
Note
”
When
“
LOCK
”
set as
“
YES
”
, temperature setting is locked,
unable to modify.
4.14.5
PID Setting
1) Press
“
menu
”
and
“
”
keys together for 3 secs., it displays
“
P
”
(proportional band);
2) Press
“
SET
”
key, the value flickers, meanwhile press
“
”
or
“
”
keys to
add or decrease the value.
3) Press
“
SET
”
key, and confirm the value.
4) Press
“
”
in turn, it displays
“
I
”
(Integration time) and
“
D
”
(Differential
time);
5) Repeat above step 2 and step 3, input and confirm the related parameter.
6) Press
“
menu
”
key, and return the running screen.
Note: the PID parameter value directly affects the temperature
control accuracy, please adjust it carefully.