44(62)
Note 2: repeat (RESET) and when it selects P6, press
+
+
simultaneously
4.15.5 Parameter Group 4
Display
Code
Name
Function Description
Parameter
Default
Default
F9
hopper n
shortage signal
detecting time
hopper 1-4 shortage signal
detecting time (0.01sec) (Note
1) (Note 2)
64
0
—
FF
FA
hopper n
discharge
detecting time
hopper 1-4 discharge detecting
time
;
(0.01sec)( Note 1)( Note
3)
1E
0
—
FF
Note 1
:
A=10 B=11 C=12 D=13 E=14 F=15
(
hexadecimal
)
Note 2
:
64= (6*16)+4=100 100*0.01=1 sec
Note 3
:
1E= (1*16)+14=30 30*0.01=0.3 sec
4.16 Alarm Instruction
1) After several loadings in shortage of material or motor overloads, the
machine stops and sends the alarm. At the moment, press
ON
OFF
key to stop
the machine. Wait till the material re-filling or trouble-shooting then start the
machine.
2) The alarm is signal output of the intermittent time
3) Alarm Code:
No.
Fault
Alarm Code
1
hopper material shortage
NM
2
motor overload
A1
3
over pressure
A2
4
abnormal power off
(
abnormal shutdown
A3
Summary of Contents for SCD-160Ux2/200H