30(62)
3) After selection, press
“
ENTER
”
key to confirm; press
“
SET
”
key, do not save
the value then exit.
4) When selects LOCK, press
“
SET
”
key during temp. setup, the SV would
display
“
LOCK
”
.
5) Default value is OFF.
4.10 Low-temp. Alarm Setup
1) When machine starts up, the low-temp. alarm function doesn
’
t work until it
gets to set alarm temperature.
2) During normal operation, if temperature long time lowers than the alarm
value and reaches alarm reaction time, low-temp. alarm would sound.
3) Low-temp. alarm value is a relative value.
4.10.1 The Value of Low-temp. Alarm
1) After F-05 setting is finished, press
“
ENTER
”
key, at this time PV displays
F-40.
Picture 4-12: Value of Low-temp. Alarm
Note: F-05 is to set over-temp. alarm, the default value is 15
℃
. It
is not allowed to modify the value.
Control temp.
Lower than low-temp. alarm value
( control temp.- low-temp. alarm value (F-40))
and higher than low-temp. reaction time
(F-41),
the alarm would sound
Start low-temp.
alarm
Set control temp.= 100
℃
Low-temp.alarm value