45(62)
5. Trouble-shooting
5.1 Error Code Instruction
Table: 5-1
:
Error code parameter
Error Code
Description
E-01
thermocouple break
E-02
power reverse, default phase
E-03
blower overload
E-04
drying temperature over EGO value
E-05
drying temperature over system maximum temperature
E-07
overheat protection (PV
≥
SV+ set value, send alarm)
E-08
memory error
E-09
honeycomb rotor fault
E-10
regeneration temperature over EGO value
E-11
thermocouple
“
+
、
-
”
wrong connection
E-12
PID auto-turning error
Failure
Possible Reason
Trouble-shooting
High dew-point
indicator lights on
1. Return air over temperature
1.Check cooling water temperature (below
40 )
℃
2. Rotor improper speed
2. Adjust motor speed regulator properly
(Default is 4)
3. Regeneration temp. improper set
3.
Reset
regeneration
temperature
( Default H5 is 80 , H4 is 150 )
℃
℃
4. Rotor blocked
4. Check or clean the rotor.
5. Filter blocked
5. Clean or replace
6. Heat-resistant air pipe leakage
6. Check air pipe or connector
7. Machine start less than 30 mins
7. Confirm it after 30 mins operation
8. Rotor not work
8. Check if motor, speed regulator or belt
has damage
9. Motor reverse running
9. Check if motor runs in reverse direction
10.System insufficient drying capacity 10. Replace large system
11.Upper & lower honeycomb cover air
leak
11. Check or replace sealing component