32(62)
time, the alarm would sound. If temperature is set as 100
℃
,
alarm time is
30min
,
after heater starts, the temperature doesn
’
t get to 95 within the
℃
first 30min, the alarm would sound.
3) The default value is OFF.
4.12 Low-temp. Alarm
1) After it reaches the set temperature, system activates the low temperature
alarm.
2) When control temp. is lower than abnormal temp. (control temp.
–
low
temp. alarm value (F-40)) and higher than low temp. response time,
system will sound alarm.
3) Even the system sounds alarm, the temperature control function is still
working.
Parameter Setting Instruction
Code
Function
Range
Reset
value
Remarks
F-03
Temp. unit
℃
,
℉
℃
-
F-04
Data lock
OFF,LOCK
OFF
LOCK is for data lock, it disables input
data
F-05
Overheat protection
temp.
0-100
℃
20
℃
Actual temp. > set temp. + overload
protection temp., it sounds alarm
F-40
Low temp. alarm value
0-100
℃
20
℃
Actual temp. < set temp.- low temp.
alarm value, it sounds alarm
F-41
Low temp. response time
OFF-99 Sec
OFF
When response time is OFF, low temp.
alarm=OFF
F-42
Heater Alarm
OFF-99 Min
OFF
The temp. not reach set value in time
unit
Control temp.
Lower than low-temp. alarm value
( control temp.- low-temp. alarm value (F-40))
and higher than low-temp. reaction time
(F-41),
the alarm would sound
Start low-temp.
alarm
Set control temp.= 100
℃
Low-temp.alarm value