background image

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT

 –

 Save these instructions for local

electrical inspector’s use.

IMPORTANT

 –

 Observe all governing codes and

ordinances.

Install the clothes dryer according to the manufacturer’s 

instructions and local codes.

Note to Installer –

 Be sure to leave these instructions 

with the Consumer.

Note to Consumer –

 Keep these instructions for future 

reference.

Clothes dryer installation must be performed by a 

qualified installer.

This dryer 

must

 be exhausted to the outdoors. 

Before the old dryer is removed from service or 

discarded, remove the dryer door.

Service information and the wiring diagram are located 

in the control console.

Do not allow children on or in the appliance. Close 

supervision of children is necessary when the appliance 

is used near children.

Proper installation is the responsibility of the installer. 

Product failure due to improper installation is not 

covered under the Warranty

.

Install the dryer where the temperature is above 50°F 

for satisfactory operation of the dryer control system.

and replace with UL-listed duct.

Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.ca

- Fire Hazard

WARNING

Clothes dryer installation must be performed by a 

qualified installer.

Install the clothes dryer according to these 

instructions and local codes.

DO NOT

 install a clothes dryer with flexible plastic 

venting materials. If flexible metal (semi-rigid or 

foil-type) duct is installed, it must be UL-listed and 

installed in accordance with the instructions found 

in “Connecting the Dryer to House Vent” later in 

this manual. Flexible vent materials are known to 

collapse, be easily crushed and trap lint. These 

conditions will obstruct dryer airflow and increase 

the risk of fire.

DO NOT

 install or store this appliance in any 

location where it could be exposed to water or 

weather.

To reduce the risk of severe injury or death, follow 

all installation instructions.

Save these instructions. (Installers: Be sure to leave 

these instructions with the customer.)

Installation   

Dryers 

Instructions 

  

This is the safety alert symbol. This symbol alerts you to potential hazards that can kill you or hurt you and others. 

words are defined as:

  

Indicates a hazardous situation which, if not avoided, 

will

 result in death or serious injury.

  

Indicates a hazardous situation which, if not avoided, 

could 

result in death or serious injury.

  

Indicates a hazardous situation which, if not avoided, 

could 

result in minor or moderate injury.

DANGER
WARNING
CAUTION

29-6075

     03-16 GE

Printed in Mexico

234D2318P006

Summary of Contents for GTX22EBMKWW

Page 1: ...re Hazard WARNING Clothes dryer installation must be performed by a qualified installer Install the clothes dryer according to these instructions and local codes DO NOT install a clothes dryer with fl...

Page 2: ...brush not included WX14X10007 LintEater Dryer rotary tube brush not included 2 ROUGH IN DIMENSIONS State of California Proposition 65 Warnings The California Safe Drinking Water and Toxic Enforcement...

Page 3: ...or test gauge connection must be installed immediately upstream of the gas supply connection to the dryer POWER CORDS GE strongly recommends the use of factory specified parts Select the power cord to...

Page 4: ...the rubber flat washer is in place and attach the dryer s long inlet hose to one male end of the Y connector Tighten by hand until firmly seated 6 Ensure the rubber flat washer is in place and attach...

Page 5: ...FF position Disconnect and discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 10 Adjustable wrenches 2 8 Pipe wrench Flat blade screwdriver Level Slip joint...

Page 6: ...nector when used must not exceed 3 feet ADJUSTING FOR ELEVATION Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or below 2000 ft elevation F...

Page 7: ...SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8 NPT elbow at t...

Page 8: ...NFPA 70 or Canadian Electrical Code CSA C22 1 This appliance must be supplied with 120V 60Hz and be connected to a properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time...

Page 9: ...2 7 7 50 1 2 Slip joint pliers Flat blade crewdriver Phillips screwdriver Level TOOLS YOU WILL NEED MATERIALS YOU WILL NEED 4 dia metal elbow 3 4 strain relief UL recognized 4 duct clamps 2 or 4 spri...

Page 10: ...lure to do so can result in death fire or electrical shock GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding w...

Page 11: ...the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 4 ground screw for Step 7 5 Install 3 4 in UL recognized strain relief to power cord en...

Page 12: ...resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the dryer to the home exhaust vent using flexible metal IRL...

Page 13: ...ill be treated like one 90 elbow For every additional 90 elbow reduce the allowable vent system length by 10 feet When calculating the total vent system length you must add all the straight portions a...

Page 14: ...nce to the exhaust airflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed...

Page 15: ...tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO SIDE OF CABINET TAB LOCATION Fire Hazard WARNING Close the back opening with cover plate Kit WE1M454 Disconnect dryer from electrical sup...

Page 16: ...sert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape as shown on the joint between the dryer internal duct and the elbow and also the joint between the elb...

Page 17: ...putty knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING THE DOOR SOLID DOOR M...

Page 18: ...er left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the original setup follow the...

Page 19: ...holes 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side 5HPRYH the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel...

Page 20: ...dryer back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 5HPRYH DQG VZDS WKH SODVWLF FDSV DQG WKH hinges 7 5RWDWH WKH RXWHU GRRU GHJU...