52
SDH Series Manual
4.5.4 Positioning test
Shihlin communication software which needs to be connected by RS-232 or USB is required to execute the positioning
test. As no external command nor any alarm occurred, positioning test could be executed.Before this operation, make
sure that the contact between SON and SG is open.
Operation
Make sure that the motor is correctly wired before this test performed. Select operation testing via Shihlin communication
software. Press “Forward” or “Reverse” to rotate the motor which will then stop after moving the command route set
by the user. Operation conditions could be modified with Shihlin communication software. The initial values and setting
ranges are listed in the table below:
Name
Initial value
Setting range
Rotary speed (rpm)
200
0~6000
Acceleration/deceleration time constant (ms)
1000
0~20000
Revolution (10kpulse)
10
0~30000
pulse (pulse)
0
0~9999
Description of the button
s:
Button name
Function description
Forward
Press to run positioning test in CCW.
Reverse
Press to run positioning test in CW.
Pause
Press “Pause” button during operation to make a temporary stop.
To press the same button which was pressed to finish the remaining route.
Otherwise, to press "Pause" button again to erases the remaining route.
Close
Terminate this test.
The motor will stop immediately if the communication cable is disconnected during operation.
The panel display like the following picture when the software becomes to position test mode.