MX-M700N ADJUSTMENTS 6 – 17
6)
Select the number that corresponds to the adjustment item
CCD (MAIN) using the numeric keypad.
This adjustment items is intended to adjust the image magnifi-
cation in the main scanning direction in original table mode
(CCD).
7)
Press the Start key.
8)
Adjust the image magnification factor by entering an appropri-
ate value through the numeric keypad.
9)
Press the P or Start key.
Pressing the Start key starts copy operation as well as applying the
adjustment value.
Repeat steps 2 to 9 until the image magnification factor is satisfac-
tory.
6-B
Adjust the image magnification in the sub-
scanning direction in original table mode
(CCD)
This adjustment is needed in the following situations:
* The CCD unit has been removed from the machine.
* The CCD unit has been replaced.
* Images are not correctly magnified in the sub-scanning direction.
* The MFP control PWB has been replaced.
* The EEPROM on the MFP control PWB has been replaced.
* The scan control PWB has been replaced.
* The EEPROM on the scan control PWB has been replaced.
* U2 trouble has occurred.
1)
Place a scale on the original table as illustrated below.
2)
Make a normal copy on A4 paper.
3)
Measure the lengths of the copied image of the scale and the
actual scale.
4)
Determine the image magnification factor using the following
formula:
Image magnification factor (%) = Copy dimension/original
dimension x 100
Example: Compare the copy and original dimensions by align-
ing the scale's 10 mm position with the copied image's 10 mm
position.
Image magnification factor (%) = 99 / 100 x 100 = 99
If the image magnification factor is within the spec (100
r
0.8%),
no adjustment is required; otherwise, do the following steps.
5)
Go through the modes specified in Simulation 48-1.
6)
Select the number that corresponds to the adjustment item
CCD (SUB) using the numeric keypad. This adjustment item is
intended to adjust the image magnification in the sub scanning
direction in original table mode (CCD).
7)
Press the Start key.
8)
Adjust the image magnification factor by entering an appropri-
ate value through the numeric keypad.
9)
Press the P or Start key.
Pressing the Start key starts copy operation as well as applying the
adjustment value.
Repeat steps 2 to 9 until the image magnification factor is satisfac-
tory.
10 20 30 40 50 60 70 80 90 100110120130140
10
20
90
100
110
10
20
90
100
110
0.8mm
100mm scale
(Original)
Copy image
(1mm (1%) shorter
than the original)
Select 2, and press
[START] key.
Press [START] key, or press
[SYSTEM SETTINGS] key.
50
1
2
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-16, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
6.LCC
(ABOVE+10: DUPLEX MODE)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-7, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.MAGNIFICATION
100
3.CCD(MAIN)
50
4.CCD(SUB)
50
5.SPF(SUB)
50
6.CIS(MAIN)
50
7.SPF(MAIN)
50
Select other than 0 - 2,
and press [START] key.
Press [SYSTEM SETTINGS] key.
Select 1, and
press [START] key.
Press [START] key.
Press [SYSTEM SETTINGS] key,
or terminate copying.
Select 0, and press [START] key.
Press [START] key, or press
[SYSTEM SETTINGS] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)