MX-M700N ADJUSTMENTS 6 – 2
4. Datails of adjustment
ADJ 1
Adjusting high voltage values
NOTE: Adjusting the output voltage requires the ability to measure
internal impedance of 1000
:
. In addition, use high voltage
probe together. (FLUKE87FLUKE80K-40 is recom-
mended.)
1-A
Adjust the main charger grid voltage
This adjustment is needed in the following situations:
* The high voltage power PWB (MC/DV/TC) has been replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
(Main charger grid voltage adjustment)
1)
Remove the rear cover of the machine.
2)
Apply a digital multi-meter to the connector CN2 pin (3) of the
high voltage PWB and the chassis GND.
3)
Go through the modes specified in Simulation 8-2.
4)
Select the number that corresponds to the adjustment item
using the numeric keypad.
5)
Press the Start key.
6)
Press the start key to have the voltage output for 30 seconds.
The operation can be stopped with the SYSTEM SETTINGS
key.
If the output voltage is not within the requirement, do the fol-
lowing steps.
7)
Enter the adjustment value using the numeric keypad.
8)
Press the Start key.
(The adjustment value is put into memory, and the correspond-
ing voltage is output for 30 seconds.)
Repeat steps 7 to 8 until the output requirement is satisfied.
ADJ13
Adjusting the fusing paper guide position
ADJ14
Adjusting the paper size detection
ADJ14A
Adjust the paper width sensor for the manual paper feed tray
40-2
ADJ14B
Adjust the paper width sensor for paper feed tray 3
40-12
ADJ14C
Adjust the paper width sensor for the DSPF paper feed tray
53-6
ADJ15
Adjusting the original size
detection (in original table mode)
ADJ15A
Adjust the detection point of the original size sensor
(in original table mode)
41-1
ADJ15B
Adjust the sensitivity of the original size sensor
41-2
ADJ16
Adjusting the touch panel coordinates
65-1
ADJ17
Adjusting the supply voltage
Job No
Adjustment item list
Simulation
Item/operation mode
Simulation
High voltage power PWB (MC/DV/TC)
Setting range
Default
Connector
Pin #
Actual voltage
Copy
Auto mode
8-2
AUTO
200 – 1000
580
CN2
3
-590
r
2v
Text mode
CHARACTER
200 – 1000
580
CN2
3
-590
r
2v
Text/photo mode
MIX
200 – 1000
580
CN2
3
-590
r
2v
Photo mode
PHOTO
200 – 1000
580
CN2
3
-590
r
2v
Printer
All modes
PRINTER
200 – 1000
580
CN2
3
-590
r
2v
FAX
All modes
FAX
200 – 1000
580
CN2
3
-590
r
2v
Press [START] key.
Press [SYSTEM SETTINGS] key.
CN2
3
SIMULATION 8-2
1
MAIN GRID SETTING. SELECT 1-6, AND PRESS START.
1.AUTO
580
2.CHARACTER
580
3.MIX
580
4.PHOTO
580
5.PRINTER
580
6.FAX
580
Press [START] key.
Press [SYSTEM SETTINGS] key.
Or after 30sec output.
SIMULATION 8-2
MAIN GRID SETTING. INPUT VALUE, AND PRESS START.
1.AUTO (200-1000)
580
SIMULATION 8-2
MAIN GRID SETTING. EXECUTING···.
1.AUTO
580