MX-M700N ADJUSTMENTS 6 – 14
5)
Adjust by turning the DSPF skew adjusting screw on the right
side of the DSPF rear frame.
Remove the hexagon cap nut of the DSPF skew adjusting
screw on the right side of the DSPF hinge and loosen the fixing
nut, then adjust by turning the DSPF skew adjusting screw
(hexagon screw).
If a < b, then turn counterclockwise the DSPF skew adjusting
screw (hexagon screw). (When the main scanning direction
print line is shifted to the left)
If a > b, then turn clockwise the DSPF skew adjusting screw
(hexagon screw). (When the main scanning direction print line
is shifted to the right)
Repeat steps 2 to 5 until an acceptable result is obtained.
[If the copied image of the paper's back side is skewed
beyond the acceptable level, do the following steps.]
6)
Remove the DSPF front cover.
7)
Change the front frame side CIS fixing position (angle) to
adjust the skew of the copied image of the paper's back side.
This adjustment should be done by loosening the CIS fixing
screw on the DSPF front side and then moving the fixing plate
in the left or right direction.
If c < d, then shift the CIS fixing plate to the right. (When the
main scanning direction print line is shifted to the left)
If c > d, then shift the CIS fixing plate to the left. (When the
main scanning direction print line is shifted to the right)
Repeat steps 2 to 7 until an acceptable result is obtained.
ADJ 5
Adjusting the image focus
The result of this adjustment will affect all image scan modes (copy,
scan, and fax).
5-A
Adjust the image focus in original table
mode and DSPF front-face mode (CCD)
This adjustment is needed in the following situations:
* The CCD unit has been removed from the machine.
* The CCD unit has been replaced.
* Copied/scanned/faxed images are not correctly focused.
1)
Go through the modes specified in Simulation 48-1.
2)
Set the adjustment item CCD (MAIN) to 50 (default).
3)
Place a scale on the original table as illustrated below.
Select 2, and press
[START] key.
Press [START] key, or press
[SYSTEM SETTINGS] key.
50
1
2
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-16, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
6.LCC
(ABOVE+10: DUPLEX MODE)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-7, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.MAGNIFICATION
100
3.CCD(MAIN)
50
4.CCD(SUB)
50
5.SPF(SUB)
50
6.CIS(MAIN)
50
7.SPF(MAIN)
50
Select other than 0 - 2,
and press [START] key.
Press [SYSTEM SETTINGS] key.
Select 1, and
press [START] key.
Press [START] key.
Press [SYSTEM SETTINGS] key,
or terminate copying.
Select 0, and press [START] key.
Press [START] key, or press
[SYSTEM SETTINGS] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)
10
20
30
40
50
60
70
80
90
100
110
120
130
140
A5
B5
A4
A5
B4
B5
A3
A4
11
8 1 2
5 1 2
A5
B5
B4
A3
A4
A5
B5
A4
8 1 2
11
13
14
17
5 1 2