MX-M700N ADJUSTMENTS 6 – 9
2)
Manually turn the scanner drive pulley, and move Scanner Unit
B until contact with the two stoppers on the CCD mounting
plate.
If Scanner Unit B makes contact with the two stoppers on the
CCD mounting plate simultaneously, the parallelism of Scan-
ner Unit B is proper.
If this requirement is not met, do the following steps.
3)
Loosen the pulley angle fixing screw on either the front or rear
frame side of Scanner Unit B.
4)
Adjust the pulley angle position on Scanner Unit B so that the
scanner unit makes contact with both of the two stoppers on
the CCD mounting plate at the same time.
5)
Fix the pulley angle on Scanner Unit B.
If the above steps fail to provide an acceptable result, then do
the following steps.
6)
Loosen the fixing screw of the scanner unit drive pulley that is
not in contact.
7)
Manually turning the scanner unit drive pulley, move Scanner
Unit B until it comes into contact with the two stoppers on the
CCD mounting plate.
8)
Without moving the scanner unit drive shaft, manually turn the
scanner unit drive pulley so that Scanner Unit B makes contact
with both of the two stoppers on the CCD mounting plate at the
same time. (Change the positional relationship between the
scanner unit drive pulley and the drive shaft.)
9)
With Scanner Unit B in contact with both of the two stoppers
on the CCD mounting plate at the same time, align the end
face of Scanner Unit A with the right-hand side end face of the
frame, and fix Scanner Unit A with the screws. (Make position-
ing by using the ruler to right side of the scanner frame (F/R)
and fix to the wire.)
Scanner Unit B
Winding pulley