MX-M700N ADJUSTMENTS 6 – 16
Repeat the above adjustments until an acceptable result is
obtained.
ADJ 6
Adjusting the image
magnification
6-A
Adjust the image magnification in the main
scanning direction in original table mode
(CCD)
This adjustment is needed in the following situations:
* The CCD unit has been removed from the machine.
* The CCD unit has been replaced.
* Images are not correctly magnified in the main scanning direc-
tion.
* The MFP control PWB has been replaced.
* The EEPROM on the MFP control PWB has been replaced.
* The scan control PWB has been replaced.
* The EEPROM on the scan control PWB has been replaced.
* U2 trouble has occurred.
1)
Place a scale on the original table in parallel with the main
scanning direction, as illustrated below.
2)
Make a normal copy on A4 paper.
3)
Measure the lengths of the copied image of the scale and the
actual scale.
4)
Determine the image magnification factor using the following
formula:
Image magnification factor (%) = Copy dimension/original
dimension x 100
Example: Compare the copy and original dimensions by align-
ing the scale's 10 mm position with the copied image's 10 mm
position.
Image magnification factor (%) = 99 / 100 x 100 = 99
If the image magnification factor is within the spec (100
r
0.8%),
no adjustment is required; otherwise, do the following steps.
5)
Go through the modes specified in Simulation 48-1.
10
20
30
40
50
60
70
80
90
100
110
120
130
140
A5
B5
A4
A5
B4
B5
A3
A4
11
8 1 2
5 1 2
A5
B5
B4
A3
A4
A5
B5
A4
8 1 2
11
13
14
17
5 1 2
Select 2, and press
[START] key.
Press [START] key, or press
[SYSTEM SETTINGS] key.
10
20
90
100
110
10
20
90
100
110
0.8mm
100mm scale
(Original)
Copy image
(1mm (1%) shorter
than the original)
50
1
2
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-16, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
6.LCC
(ABOVE+10: DUPLEX MODE)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-7, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.MAGNIFICATION
100
3.CCD(MAIN)
50
4.CCD(SUB)
50
5.SPF(SUB)
50
6.CIS(MAIN)
50
7.SPF(MAIN)
50
Select other than 0 - 2,
and press [START] key.
Press [SYSTEM SETTINGS] key.
Select 1, and
press [START] key.
Press [START] key.
Press [SYSTEM SETTINGS] key,
or terminate copying.
Select 0, and press [START] key.
Press [START] key, or press
[SYSTEM SETTINGS] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)