MX-M700N ELECTRICAL SECTION 11 – 18
4. Signal name list
Signal name
Name
Function/Operation
Connector level
Connector
No.
Pin
No.
PWB
name
Remark
“L”
“H”
/MIMA
Scanner motor control signal
(Phase /A)
Scanner motor control (Phase /A)
—
—
7
3
SCN
/MIMB
Scanner motor control signal
(Phase /B)
Scanner motor control (Phase /B)
—
—
7
4
SCN
/SLUMB
DDSPF paper feed tray lift-up
motor control signal
(Phase /B)
DSPF paper feed tray lift-up motor
control (Phase /B)
—
—
11
2
SCN
/SLUMA
DSPF paper feed tray lift-up
motor control signal
(Phase /A)
DSPF paper feed tray lift-up motor
control (Phase /A)
—
—
11
1
SCN
/SPFMA
DSPF motor control signal
(Phase /A)
DSPF motor control (Phase /A)
—
—
12
11
SCN
/SPFMB
DSPF motor control signal
(Phase /B)
DSPF motor control (Phase /B)
—
—
12
15
SCN
/VIDEO
Image data signal
Image signal to LSU (PCU output)
—
—
22
23
PCU
38VMON
38V monitor signal
Detection of 38V for interlock
OFF
ON
19
14
PCU
ACMON
AC waveform monitor signal
SUB power source AC wave high
value monitor (For heater lamp ON
control) (Phase control)
—
—
1
3
PCU
ADD_CCD1
CCD serial data area
identification number (CCD)
Identification of address data and
image data area in CCD serial data
—
—
1
66
SCN
ADD_CCD2
CIS serial data area
identification number (CIS)
Identification of address data and
image data area in CIS serial data
—
—
10
13
SCN
ADM1A
Duplex (ADU) motor 1
(Upstream side) control signal
(Phase A)
Duplex (ADU) motor 1 (Upstream)
control (Phase A)
—
—
10
9
PCU
ADM1B
Duplex (ADU) motor 1
(Upstream side) control signal
(Phase B)
Duplex (ADU) motor 1 (Upstream)
control (Phase B)
—
—
10
11
PCU
ADM1XA
Duplex (ADU) motor 1
(Upstream side) control signal
(Phase /A)
Duplex (ADU) motor 1 (Upstream)
control (Phase /A)
—
—
10
10
PCU
ADM1XB
Duplex (ADU) motor 1
(Upstream side) control signal
(Phase /B)
Duplex (ADU) motor 1 (Upstream)
control (Phase /B)
—
—
10
12
PCU
ADM2A
Duplex (ADU) motor 2
(Downstream side) control
signal (Phase A)
Duplex (ADU) motor 2 (Upstream)
control (Phase A)
—
—
10
13
PCU
ADM2B
Duplex (ADU) motor 2
(Downstream side) control
signal (Phase B)
Duplex (ADU) motor 2 (Upstream)
control (Phase B)
—
—
10
15
PCU
ADM2XA
Duplex (ADU) motor 2
(Downstream side) control
signal (Phase /A)
Duplex (ADU) motor 2 (Upstream)
control (Phase /A)
—
—
10
14
PCU
ADM2XB
Duplex (ADU) motor 2
(Downstream side) control
signal (Phase /B)
Duplex (ADU) motor 2 (Upstream)
control (Phase /B)
—
—
10
16
PCU
AINPD
Duplex (ADU) paper entry
detection signal
Duplex (ADU) paper entry
detection, detection of paper exit to
finisher
Paper pass
—
7
28
PCU
APPD1
Duplex (ADU) paper pass
detection signal 1
Duplex (ADU) upstream paper
pass detection
Paper pass
—
7
24
PCU
APPD2
Duplex (ADU) paper pass
detection signal 2
Duplex (ADU) midstream paper
pass detection
Paper pass
—
7
26
PCU
AUD
Auditor installation detection
signal
Auditor installation detection
Counter
available
5
5
SCN
BUP-PRout
Power save mode relay signal
Selection of power save mode and
normal power mode
Relay OFF
Relay ON
19
9
PCU
BZR
Buzzer signal
Key touch sound buzzer signal
Ring
1
86
SCN
CA
Clear all (Auditor) signal
Clear all (Auditor)
Clear
5
3
SCN
CCDFAN
CCD fan motor control signal
CCD fan motor control
ON
1
17
SCN
Not used.
CCFT
Backlight control signal
Backlight control
ON
1
94
SCN
CFM-DC1
Cooling fan motor control
signal (Power source)
Power cooling fan motor control
Max. force
of wind
Stop
19
3
PCU
CFM-DC2
Cooling fan motor control
signal (Power source)
Power cooling fan motor control
Max. force
of wind
Stop
19
4
PCU
CFM-DV
Cooling fan motor control
signal (Developing)
Developing cooling fan motor
control
Max. force
of wind
Stop
7
3
PCU
CFM-R1
Cooling fan motor control
signal (LSU/Process section)
Cooling fan motor control
(LSU, process section)
Max. force
of wind
Stop
21
3
PCU
CFM-R2
Cooling fan motor control
signal (LSU/Process section)
Cooling fan motor control
(LSU, process section)
Max. force
of wind
Stop
21
4
PCU