SGM Technology for Lighting
GB
User’s Manual 1.03
- 30 -
Palco Series
T
EST FUNCTIONS
Using the test menu, it’s possible to test the correct operation of the channels that control the Palco.
1.
Use the UP/DOWN keys to find the “TEST” menu
2.
Press “Enter” and hold it down for a few seconds to confirm the choice.
The text on the display will begin to flash.
3.
Use the UP/DOWN keys to select the physical channel to be tested
(ALL - SHUTT - DIMMR - RED - GREEN - BLUE - CTC)
4.
Press “Enter” and the selected text will begin to flash, running a test
routine on the chosen channel.
5.
Press “Enter” again to exit the routine being run and choose another
channels to be tested
6.
Keep “Enter” pressed down for a few seconds if you wish to exit the
TEST menu
T
EMPERATURA
Using the TEMPERATUR menu it is possible to display the actual temperature. Palco 3 indicates only the
temperature of the head of the fixture, while Palco 5 indicates also the temperature of the fixture base.
In case of critical heat conditions, it is very important to know the temperature of Palco, as the unit is
provided with a LED self-protection system which reduces the overall power emission when Palco is
operating at too high temperatures.
1.
Using the UP/DOWN keys, select the menu "TEMPERATUR"
2.
Press the "Enter" key to instantaneously display the actual temperature
3.
Using the UP/DOWN keys, it is possible to display the temperature in
Celsius or Fahrenheit
4.
Press "Enter" to quit the TEMPERATUR menu
C
ONFIGURING A
M
ASTER
When a system with several interconnected fixtures has to be used in Stand-alone mode, there has to be
one MASTER fixture, able to control the other fixtures, via appropriate on-board programming.
1.
Use the UP/DOWN keys to find the “MASTER” menu
2.
Press “Enter” and the displayed text will immediately begin to flash
3.
Use the UP/DOWN keys to choose ON or OFF status
4.
Press “Enter” to exit the MASTER menu
C
ONFIGURING
S
LAVES
When a system with several interconnected fixtures has to be used in Stand-alone mode, there has to be
one MASTER fixture, whereas each of the fixtures controlled by it must be individually configured with its
own SLAVE number. In the event of the same ID being used for several fixtures, they will not be able to
be controlled individually by the MASTER program.
1.
Use the UP/DOWN keys to find the “SLAVEID” menu
2.
Press “Enter” and the displayed text will immediately begin to flash
3.
Use the UP/DOWN keys to choose the required ID (from 1 to 29)
4.
Press “Enter” to exit the SLAVEID menu and confirm
SLAVEID=12
MASTER=ON
HEAD=21°C
BASE=21°C
TEMPERATUR
TEST=BLUE