SGM Technology for Lighting
GB
User’s Manual 1.03
- 12 -
Palco Series
2
I
NSTALLATION
2.1
Unpacking the fixture
Before installing the fixture, make sure that the packing contains the items indicated in the following list
and the fixture has not been damaged.
In case of doubts, do not use the fixture and contact an SGM authorised assistance service centre and
the transportation company. The consignee only can claim for damages to the fixture caused during
transportation.
1 Palco Series projector
6mm UNI 6 setscrew wrench
3 mm UNI 67 setscrew wrench
PG9 black threaded plug
NIC brass counter nut
ORM 0130-15 O-ring seal
Display cover
User manual
DO NOT DESPERD THE PACKING ELEMENTS.
THE PACKING ELEMENTS (PLASTIC BAGS, FOAM, NAILS, ETC.), MUST NEVER BE LEFT NEAR CHILDREN, AS
DANGEROUS. USE THE ORIGINAL PACKAGE IN CASE OF FIXTURE RETURN TO THE MANUFACTURER FOR REPAIR OR
MAINTENANCE SERVICE, IT HAS BEEN SPECIFICALLY MADE TO PROTECT THE FIXTURE DURING THE TRANSPORT.
2.2
Mounting the fixture
ATTENTION!
Before installing the fixture, make certain the AC mains cable is disconnected.
W
IRING
Being a fixture protected to IP65, the unit is already fitted with wiring and dedicated cable gland. Palco
only requires its AC plug to be wired, following the indications below:
Simbolo
Pin
EU
US
UK
L
Live
Brown
Yellow/Copper
Red
N
Neutral
Blue
Silver
Black
Ground
Yellow/Green
Green
Green
ATTENTION!
Wiring and connection work must be carried out by experienced qualified staff.
Class one equipment must be earthed (grounded)
Do not power Palco units with dimmers, as this could damage their on-board power
supply
Before connecting the unit, make certain that the mains power supply is the same
as indicated on the fixture’s ID plate
The unit must be protected by a thermal/magnetic circuit-breaker
Palco is controlled via DMX 512 serial digital signal. Cables for connection to the signal (supplied) are
fitted with standard XLR 5-Pin connectors. It is indispensable to use cables that meet EIA RS-485
specifications to connect the fixtures to the control console.
NOTE FOR USA AND CANADA
The version of the light with ETL/UL certificate, for US and Canadian markets, does not come with the
DMX cable. It will be the responsibility of the installer to set up the light with a cable with the
appropriate specifications for the type of installation. We recommends to use for outdoor installation the
Belden cable 7921A UL certified type CMX-outdoor. For these versions come with DMX out-door XLR
connectors.