DIGITAL WEIGHING INDICATOR
SI 4500
- 27 -
“STEADY” condition check time setting
F12
03
0
∫
20
During the set time period, estimate weighing part’s “STEADY” condition and
display.
If you set small value, indicator will take “STEADY” fast, if you set large value,
indicator will take “STEADY” slow.
Display Up-date rate selection
F13
●
0
About 10ms
1
About 30ms
2
About 50ms
∫
∫
8
About 170ms
9
About 190ms
(FINAL, PRE1, Free Fall, No of BIN) Set value apply selection
F14
●
0
Apply only certain P/N
1
Apply same set value to all P/N
BATCH Process Back-Up Mode
F15
●
0
Normal Mode (Batch Process will not be saved)
1
Back-Up Mode (Batch Process will be saved)
Minus(-) symbol display selection
F16
●
0
Display (-) symbol on the display
1
Not use
“NEAR ZERO” relay output mode selection
F17
●
0
Display weight is Zero(Including “TARE” Zero)
Near Zero relay output
1
Only Gross Zero(Net TARE)
Near Zero relay output
Equipment No. setting
F18
01
01
∫
99
Equipment No. setting with No. key.
(01 ~99 settable)