5-5 F-Function Detailed information
■
General Function Setting
(
●
Factory default set value)
Weighing Data Save Method Selection
(Apply on Accumulated weighing count/weight)
F01
●
0
Manual Save Mode (Save when “Print” key input)
1
Automatic Save Mode(Save when Batch Finished)
Weight-Back up selection
F02
●
0
Normal Mode
1
Weight Back up Mode
Motion Band Range setting
F03
06
1
∫
50
This is set “Steady” acceptable range of weighing part.
If there is vibration on weighing part, you can set this function and reduce the
vibration effect on weighing process.
1 : Weak vibration
∫
50 : Strong Vibration
Zero Tracking Compensation Range setting
F04
2
0
∫
9
Due to external causes(Temperature, wind, and dust), there are small weight
difference, indicator will ignore the weight difference and display Zero.
For this compensation function, indicator will estimate the weight difference is
over the set range during fixed time period.
If there is large weight difference over set range within fixed time period, the
“Zero” is breaking and will find new zero point.
Auto Zero Range setting
F05
00
00
∫
99
Within the “Auto Zero” range, weighing part is steady, indicator will display
current weight as “Zero”
If the weighing part is not “Steady”, indicator will display current weight.
(Auto Zero Range : ± Set value + weight unit)