DIGITAL WEIGHING INDICATOR
SI 4500
- 9 -
1. Save set value during setting process.
2. Calibration mode
- Save current setting and move to next step.
3. F-Function mode
- Save current F-function setting, and move to next F-function
1. “F-TEST” Mode Entrance : Press “F” key for 5sec.
2. Under “F-function Mode”, Move to next Function or move to certain function No.(Press
function No. and press “F” key)
3. Function key (Refer “Function keys”)
Enter/Exit to “Calibration” mode.
“ON” : Enter to Calibration Mode.
“OFF” : Exit from Calibration Mode.
※
Function Keys (Combined Key functions)
Function Key
Contents
Print all P/Ns’ accumulated weighing count and weight.
(Grand-Total Print)
Print current P/N’s accumulated weighing count and weight.
(Sub-Total Print)
Set Total No. of BIN, which will be used for current Batch process.
Max. 16kinds Bins will be settable or single process.
Not using BIN
: Must set “FINAL” value as “0”.
Using BIN
: Must set “FINAL”, “PRE1”, “Free Fall”.
Set “Over N.G”(Error relay) range.
(If you set larger value than FINAL value, the setting is not saved)
Set “Under N.G”(Error relay) range.
(If you set larger value than FINAL value, the setting is not saved)