![Sewha si 4500 Operation Manual Download Page 8](http://html.mh-extra.com/html/sewha/si-4500/si-4500_operation-manual_1250420008.webp)
DIGITAL WEIGHING INDICATOR
SI 4500
- 8 -
Can set Max. 50kinds different “Mixing Formulas” with this key.
And call saved mixing formula, too.
Formula save : Choose certain P/N and each Bin’s set vale.
Formula call : P/N + Number key + Enter
Set each material’s set value with this key.
※
Each Bin has its own “FINAL”, “PRE 1”, “Free Fall” set values.
FINAL value set : Final + Number key + Enter
PRE 1 value set : Pre1 + Number key + Enter
Set each Bin’s Final set value with this key.
FINAL value set : FINAL + Number key + Enter
FINAL value Check : Press FINAL
Display during 5sec
Set each Bin’s PRE 1 set value with this key.
PRE1 value set : PRE1 + Number key + Enter
PRE1 value Check : Press PRE1
Display during 5sec
Set each Bin’s Free Fall value and control FINISH relay in advance.
Free Fall value setting : Free Fall + Number key + Enter
Free Fall value check : Press Free fall
Display during 5sec
1. Manual Print (F38-00 setting, under F35-01)
2. Manual weighing Data save for accumulated weighing count and weight.
(F01-00 / 02 setting)
3. Calibration mode
- Digit setting
Whenever pressing “0”key, digit will be change 1, 2, 5, 10, and 50.
- Decimal point position
Whenever pressing “0”key, decimal point will be change.
1. Modify the set value during setting process.
2. Calibration mode
- Move back to previous step.
F-function Mode.
- F-function Exit : Press “Clear” key, once.
- F-Test Mode Exit : Press “Clear” key, twice.