![Sewha si 4500 Operation Manual Download Page 35](http://html.mh-extra.com/html/sewha/si-4500/si-4500_operation-manual_1250420035.webp)
DIGITAL WEIGHING INDICATOR
SI 4500
- 44 -
8
76,800bps
9
115,200bps
DATA Transference Method selection
F62
●
0
Simplex Mode / Stream Mode
1
Duplex Mode / Command Mode
Print port selection (Under F62-01 setting, only)
F63
●
0
Same port as using for Command Mode.
1
The other port.
“Check-Sum” detection selection (Under F62-01 setting, only)
F64
●
0
Check-Sum data will not be included on transferred data.
1
Check-Sum data will be included on transferred data.
Serial Port Application Selection (Under F62-00 setting, only)
F65
●
0
DATA Transference purpose
1
Printing purpose (Serial Printer)
DATA Transference Mode selection (Under F62-00, F65-00 setting, only)
F66
●
0
Stream Mode : Weighing Data will be transferred continuously.
1
Finish Mode : When Finish Relay output, only 1 time transferred.
2
Manual Mode : When “Print” key input, 1 time transferred.
DATA Transference Format selection(Under F62-00, F65-00 setting, only)
F67
●
0
Format 1.
1
Format 2. (Format 1 + ID No.)
2
CAS Format
Print Mode selection (Under F32-00, F35-01 setting, only)
F68
●
0
Manual Print : Whenever “Print” key input.
1