DIGITAL WEIGHING INDICATOR
SI 4500
- 21 -
After finishing input, press
key and save and move to next step.
Caution
※
※
※
※
If the plural No. of load cells are installed, please make sum the all load cells capacity and input.
Ex) There are 4pcs of load cells are installed, and each load cell’s Max. capacity is 1,000kg.
Then, total Max. Capacity will be 4,000kg and you have to input 4,000kg.
Step No.2 - Setting “Decimal Point”
Enter the Decimal point input mode
Input Decimal point and Press Enter to move next step
Under this step, define the optimal position or Decimal point.
Whenever pressing
key, Decimal point will be changed, like XXX. – XX.X – X.XX - .XXX
The Max. Decimal point will be third place under Zero.
On the Optimal position, stop pressing
key and press
key to save and move to next step.
Step No.3 - Setting “Digit / Division” value.
Enter the division input mode
Select optimal division with pressing
“o” key
Press Enter key and move to next
step.
Under this step, define the optimal Digit/Division value of weighing measurement.
Whenever pressing
key, the Digit/Division value will be changed, like 01-02-05-10-50.
On the optimal Digit/Division value, stop pressing
key and press
key to save and
move to next step.
Caution
※
※
※
※