6
Startup of MOVIMOT
®
with MLK.. in Easy mode
Description of the DIP switches S1
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
52
Motor with operating point 400 V/50 Hz and LSPM technology
Applies to MOVIMOT
®
with the following drive ID module:
Drive ID module
Motor
Identification
Identification
color
Part number
Line voltage
V
Line frequency
Hz
DRU...J/400/50
Gray
28203194
230/400
50
Setting of DIP switch S1/6:
Power rating
Motor type
MOVIMOT
®
inverter MM..D-503-00
Motor in
W
connection
Motor in
m
connection
kW
S1/6 = OFF
S1/6 = ON
S1/6 = OFF
S1/6 = ON
0.25
DR
U
71SJ/..
–
MM
03
D..
MM
03
D..
MM
05
D..
0.37
DR
U
71MJ4/..
MM
03
D..
MM
05
D..
MM
05
D..
MM
07
D..
0.55
DR
U
80SJ4/..
MM
05
D..
MM
07
D..
MM
07
D..
MM
11
D..
0.75
DR
U
80MJ4/..
MM
07
D..
MM
11
D..
MM
11
D..
MM
15
D..
1.1
DR
U
90MJ4/..
MM
11
D..
MM
15
D..
MM
15
D..
MM
22
D..
1.5
DR
U
90LJ4/..
MM
15
D..
MM
22
D..
MM
22
D..
MM
30
D..
2.2
DR
U
100MJ4/..
MM
22
D..
MM
30
D..
MM
30
D..
MM
40
D..
3.0
DR
U
100LJ4/..
MM
30
D..
MM
40
D..
MM
40
D..
–
6.5.4
DIP switch S1/7
Setting the maximum PWM frequency
•
When DIP switch S1/7 is set to "OFF", the MOVIMOT
®
works with the PWM fre-
quency of 4 kHz.
•
When DIP switch S1/7 is set to "ON", the MOVIMOT
®
works with the PWM fre-
quency of 16 kHz (low-noise). MOVIMOT
®
incrementally switches back to lower
clock frequencies depending on the heat sink temperature and the load on the in-
verter.
6.5.5
DIP switch S1/8
No-load vibration damping
When setting DIP switch S1/8 to "ON", this function reduces resonance vibrations
when in no-load operation.
27792307/EN – 07/2022