5
Electrical installation
Connection of MOVIMOT® MM../AZSK (connection option B)
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
32
5.4
Connection of MOVIMOT
®
MM../AZSK (connection option B)
Connection
of
MOVIMOT®
MM../AZSK
(connection
option B)
The following figure shows the connection in MM../AZSK design:
M
3~
L1
L2
L3
PE
K11
F11/F12/F13
X1: 13
X1: 14
X1: 15
X1: L1
X1: L2
X1: L3
RD
WH
BE/BR
MM../AZSK
BU
X10:1 X10:2 X10:3
BW [4]
[5]
4
2
1
3
3
1
4
2
24V
4
2
1
3
4
2
1
3
3
1
4
2
AS-Int
AS-Interface -
24 V
DI3
VO24
3
1
4
2
DI2
[1]
[2]
[3]
BK
YE
BK
V0
X02
X03
X01
X02
X03
X01
36028798141969035
AZSK plug connector
[1]
X01:
M12 plug connector
(male, black)
1 24 V
24 V supply (AUX PWR)
2 N.C.
Not connected
3 0 V
Reference potential AUX PWR
4 N.C.
Not connected
[2]
X02:
M12 plug connector
(male, yellow)
1 AS-Int
AS-Interface signal cable +
2 0 V
Reference potential AUX PWR
3 AS-Interface -
AS-Interface signal cable -
4 24 V
24 V supply (AUX PWR)
[3]
X03:
M12 plug connector
(female, black)
1 VO24
24 V voltage supply for sensors
2 DI3
DI3 sensor input
3 V0
'
0 V reference potential for sensors
4 DI2
DI2 sensor input
5 PE
PE
[4]
BW.. braking resistor (only for MOVIMOT
®
without mechanical brake)
[5]
Plug connector for connecting the BEM option
27792307/EN – 07/2022