6
Startup of MOVIMOT
®
with MLK.. in Easy mode
Description of the DIP switches S2
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
53
6.6
Description of the DIP switches S2
6.6.1
DIP switch S2/1
Brake type
•
When using the standard brake, the DIP switch S2/1 must be set to "OFF".
•
When using the optional brake, the DIP switch S2/1 must be set to "ON".
Motor
Standard brake
[type]
Optional brake
[type]
400 V/50 Hz
460 V/60 Hz
50/60 Hz voltage range
380 V/60 Hz
ABNT
Brazil
400 V/50 Hz
LSPM
Technology
S2/1 = OFF
S2/1 = ON
DR63L4
BR03
–
DR2S63M4
BE03
BE03
DRN71MS4
DRN71MS4
BE03
BE05
DRS71S4
DRE80S4
DR2S71MS4
DRN71M4
DRN71MK4
DRS71S4
DRN71M4
DRE71SJ4
DRU71SJ4
DRU71MJ4
BE05
BE1
DRS71M4
DRS80S4
DRE80M4
DR2S71M4
DR2S80MK4
DRN80MK4
DRN80M4
DRS71M4
DRE80S4
DRN80MK4
DRN80M4
DRE71MJ4
DRU80SJ4
BE1
BE05
DRP90M4
DRU80MJ4
BE1
BE2
DRS80M4
DRE90M4
DRP90L4
DR2S80M4
DRN90S4
DRE80M4
DRN90S4
DRE80SJ4
DRU90MJ4
BE2
BE1
DRS90M4
DRE90L4
DR2S90S4
DRN90L4
DRE90M4
DRN90L4
DRE80MJ4
BE2
BE1
DRP100M4
DRU90LJ4
BE2
BE5
DRS90L4
DRE100M4
DRE100L4
DRP100L4
DR2S90L4
DRN100LS4
DRE90L4
DRE90MJ4
DRE90LJ4
DRU100MJ4
BE5
BE2
DRS100M4
DRS100L4
DRS100LC4
DRE100LC4
DR2S100LS4
DR2S100L4
DRN100L4
DRN100LM4
DRE100M4
DRE100L4
DRN100L4
DRN100LM4
DRE100MJ4
DRU100LJ4
BE5
BE2
DRP112M4
DRE132S4
DRP112S4
DRN112M4
BE5
BE11
Preferred brake voltage
MOVIMOT
®
type (inverter)
Preferred
brake voltage
MOVIMOT
®
MM..D-503, size 1
(MM03.. – MM15..)
230 V
MOVIMOT
®
MM..D-503, size 2
(MM22.. – MM40..)
120 V
MOVIMOT
®
MM..D-233, sizes 1 and 2
(MM03.. – MM22..)
6.6.2
DIP switch S2/2
Brake release without enable
When switch S2/2 is set to "ON", it is possible to release the brake even if there is no
drive enable.
This function is only available for brakemotors.
This function is not available in hoist operation.
27792307/EN – 07/2022