5
Electrical installation
Connection of MOVIMOT® MM../AVSK (connection option A)
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
31
5.3
Connection of MOVIMOT
®
MM../AVSK (connection option A)
Connection
of
MOVIMOT®
MM../AVSK
(connection
option A)
The following figure shows the connection in MM../AVSK design:
M
3~
L1
L2
L3
PE
K11
F11/F12/F13
X1: 13
X1: 14
X1: 15
X1: L1
X1: L2
X1: L3
RD
WH
BE/BR
MM../AVSK
BU
X10:1 X10:2 X10:3
X02
BW [2]
[3]
[4][5][6][7]
4
2
1
3
3
1
4
2
AS-Int
AS-Interface -
24 V
[1]
YE
[8][9]
24V X5: 2
X5: 1
X6: 1,2
X6: 3,4
X6: 6
X6: 5
V0
V024
DI2
DI3
X02
36028798139859083
AVSK plug connector
[1]
X02:
M12 plug connector
(male, yellow)
1 AS-Int
AS-Interface data cable +
2 0 V
Reference potential AUX PWR
3 AS-Interface -
AS-Interface data cable -
4 24 V
24 V supply AUX PWR
[2]
BW.. braking resistor (only for MOVIMOT
®
without mechanical brake)
[3]
Plug connector for connecting the BEM option
[4]
DI2 sensor input
[5]
DI3 sensor input
[6]
24 V voltage supply for sensors
[7]
0 V reference potential for sensors
[8]
24 V supply AUX PWR (only for MLK30A and MLK31A)
[9]
Reference potential AUX PWR (only for MLK30A and MLK31A)
27792307/EN – 07/2022