Installing the sensor cable
FlexPS Product Guide
Page 47
Installing cable on barbed wire
Refer to
Climb-over deterrent hardware on page 9
.
•
Take care not to damage the sensor cable on the barbs during installation.
•
Ensure that there is no possibility of subsequent damage from the barbs.
•
Attach the sensor cable to the barbed wire using UV-resistant cable ties.
•
If the barbed wire array contains three or more wires, attach the sensor cable to the top wire.
•
If the wires in the array are less than 10 cm (4 in.) apart, use a saw-tooth pattern.
On razor ribbon
•
Attach the sensor wire to the outer perimeter of the coil (see
•
Use stiffening wires to prevent the concertina from moving.
Installing cable on weld-mesh fence
•
Install the sensor cable on the secure side of the fence (the side opposite the threat).
•
Sensor cable being installed on the same side of the fence as the horizontal wires should be
placed directly below the horizontal wire and attached every 25 cm (10 in.).
•
Sensor cable being installed on the opposite side of the fence as the horizontal wires should
be attached at the intersection points of the two wires every 25 cm (10 in.).
Note
Senstar recommends the use of Armour-FLEX sensor cable for
instances where the cable is attached to barbed wire or razor ribbon.
Note
Follow the installation instructions and use the height
recommendations for chain-link fences when installing sensor
cable on weld-mesh fence.
Figure 53: Weld-mesh fence
sensor cable on the same side as the horizontal wires
sensor cable on the opposite side of the horizontal wires
sensor cable
cable tie
attach sensor cable snugly
to the horizontal wire
attach sensor cable
to the intersection of
the horizontal and
vertical wires
sensor cable