Installing the sensor cable
Page 28
FlexPS Product Guide
At fence posts
•
Secure the cable at both sides of each fence post so the cable is in contact with the post. The
cable should have enough slack so that it is not stressed, but be tight enough so that it can not
easily move.
At corners or heavier gauge posts
Install a sensitivity loop at all fence corners and at any heavier gauge fence posts.
Service loops
•
Install U-shaped service loops approximately 15 m (50 ft.) apart along the sensor cable run.
The loop should measure 30 to 45 cm from top to bottom. Install service loops at fence posts.
•
For a double cable pass create two equally spaced service loops in the same manner as for a
single cable pass.
Figure 19: Cable at fence posts
Figure 20: Sensor cable at corner and at heavier gauge posts
secure the cable at both sides of each fence post
sensor cable
fence post
single cable pass
double cable pass
sensitivity loops at corner posts
sensor cable
chain-link or weld-mesh fence
1/4
fence
height
1/4
height
fence