Lists of function parameters
40
Paramete
r
Name
Setting Range and Description
Factory
settings
Mod
ificat
ion
Page
F4-13
Terminal Working
Mode
0: Single-wire mode (startup/shutdown)
1: Two-Wire Mode 1 (anticlockwise)
2: Two-Wire Mode 2 (startup/shutdown and
direction)
3: Two-Wire Mode 3 (startup/shutdown)
4: Three-Wire Mode 1
(clockwise/anticlockwise and shutdown)
5: Three-Wire Mode 2 (operation, direction and
shutdown)
1 ×
102
F4-14
Debouncing Time of
Digital Input
Terminal
0—2,000ms 10ms
○
104
F4-15
UP/DOWN
Adjustment
0: Terminal level mode
1: Terminal pulse mode
2: Control panel level mode
3: Control panel pulse mode
0
○
104
F4-16
UP/DOWN Rate/Step
Length
0.01—100.00; unit: %/s or %
1.00
○
104
F4-17
UP/DOWN Memory
Options
0: Storage on poweroff
1: Reset on poweroff
2: Reset on shutdown or poweoff
0
○
104
F4-18
UP/DOWN Upper
Limit
0.0—100.0%
100.0%
○
104
F4-19
UP/DOWN Lower
Limit
-100.0—0.0%
0.0%
○
104
F4-20
—F4-26
Multi-Band
Frequency (1—7)
0.00—650.00Hz
The factory settings of Multi-Band Frequency
1 through to Multi-Band Frequency 7 are their
respective Multi-Band Frequency Numbers.
Example: The factory setting of Multi-Band
Frequency 3 is 3.00Hz
n.00Hz
(n=1—7)
○
105
Frequency Bands and Corresponding Parameters
F5: Settings of Digital Output and Relay Output
Paramete
r
Name
Setting Range and Description
Factor
y
setting
s
Mod
ificat
ion
Page
F5-00
Functions of
Digital Output
Terminal Y1
0: Inverter ready for
operation
±31: Motor #4 in
line-frequency operation
1
×
105
n
1
2
3
4
5
6
7
Frequency
Band n
F4-20 F4-21 F4-22 F4-23 F4-24 F4-25 F4-26
Summary of Contents for SB200 Series
Page 4: ......