Lists of function parameters
34
Para
meter
Name
Setting Range and Description
Factory
Settings
Modifi
cation
Pag
e
F0-03
Frequency Setting
Retention Mo
de
Units digit: Storage option on Power Failure
0: Stores the main frequency settings modified by
pressing
or by communication to F0-00
upon poweroff
1: Does not store the main frequency settings
modified by pressing
or by
communication upon poweroff
Tens digit: Retention options on shutdown
0: Retains the main frequency settings modified by
pressing
or by communication upon
shutdown
1: Restores the main frequency settings modified by
pressing
or by communication upon
shutdown to F0-00
00
○
79
F0-04
Auxiliary Setting
Channel Options
0: Unavailable
1: F0-00
2: UP/DOWN adjustment
3: AI1
4: AI2
5: AI3
6: PFI
0
○
79
F0-05
Auxiliary Channel
Gain
-1.000—1.000
1.000
○
79
F0-06 Max. Frequency
F0-07—650.00Hz
50.00Hz
×
79
F0-07
Upper Frequency
Limit
F0-08 “Lower Frequency Limit”—F0-06 “Max.
Frequency”
50.00Hz
×
79
F0-08
Lower Frequency
Limit
0.00Hz—F0-07 “Upper Frequency Limit”
0.00 Hz
×
80
F0-09 Direction Lock
0: Clockwise and anticlockwise direction
1: Clockwise direction lock
2: Anticlockwise direction lock
0
○
80
F0-10
Parameter Write
Protection
0: Inapplicable
1: Applicable to all parameters but F0-00 and F7-04
2: Applicable to all parameters
0
○
80