7. MAINTENANCE
7.1.
FIREBOX MAINTENANCE
Soot and other dirt will cover the interior of your fireplace depending on
the rate of usage. Soot and dirt lead to a low efficiency rate of your fireplace
and decrease the heat exchange.
Therefore, we recommend
cleaning of interior walls of the firebox
with a brush at least once in a year
, if needed even more times.
Tighten the handle safety bolt located on the firebox door with a
crosshead screwdriver only if needed.
7.2.
MAINTENANCE DURING SUMMER
Clean the firebox, chimney and ash box thoroughly. If the room with the
fireplace is very humid, we recommend putting salt in a container into the
firebox. The salt will absorb the humidity.
7.3.
AUTOMATIC REGULATOR
When replacing the automatic regulator, adhere to the following procedure:
loosen 3 bolts (Figure 15b and c) and remove the automatic
regulator lid, which is located on the rear side of the fireplace,
pull out the probe from the boiler
– Figure
15 d
,
maximum allowed prob
e temperature is 90°C
! The warranty is
void if the probe temperature exceeds the maximum value!
straighten the capillary that contains the probe and pull it out
through the opening located on the lid of the automatic regulator,
pull out the cable, which is connected to the automatic regulator
–
Figure
15e
and
f
,
loosen 4 M6 bolts with a wrench
– Figure
15g
and
h
,
remove and change the automatic regulator.