SENKO fireplaces
–
Instruction manual
39
10. TECHNICAL DATA
SENKO fireplace
Central
20-25 kW
Central
30-35 kW
Nominal heat output
, kW
25
35
Boiler
, kW
20
31
Room
, kW
5
4
Amount of water in boiler
,
L
32
55
Operating pressure (max)
, bar
3
Operating temperature
, °C
85
Width
, mm
650
850
Depth,
mm
750
870
Height,
mm
1150
1250
Weight,
kg
155
240
Firebox opening (W × H)
, mm
510×350
675×465
Firebox (W × D)
, mm
475×385
620×465
Firebox volume
, dm
3
65,4
137,8
Fuel consumption
, kg/h
9
10,5
Ash pan
, L
7,5
10,5
Flue gases exhaust
, mm
200
Flue gas temperature
, °C
310
370
Required flue draught
, Pa
12
15
CO in flue gases at
13% O
2
, %
0,3
0,2
Flue gas mass flow rate
, g/s
25,5
39,5
Efficiency
, %
80
69
Regulation
Primary air
automatic
Secondary air
Certified in accordance with EN norm
EN 13229
-
technical specification apply to wood and wooden briquettes used as fuel
-
technical specifications are indicative and may vary as such. The manufacturer
withholds the right to change any technical specification to further improve the
products