SENKO fireplaces
–
Instruction manual
29
5.2.
FIRING
5.2.1. PROCEDURE
Prior to every firing,
follow the following procedure :
vent damper on the chimney open until the end (move the lever
fully to the left),
open the primary air inlet,
open the firebox door (maximum door opening angle is 90
),
put the kindle wood into the firebox and ignite it,
close the firebox door,
monitor flame progression through the firebox door,
once the fire is in full flame, add wooden logs as necessary,
regulate the fire intensity by regulating the volume of primary air via
automatic regulator,
wide grate (16) openings must be positioned facing upwards at all
times to allow the ashes to fall down.
WARNING!
Never use flammable liquids, such as petrol and similar
to ignite the fire and always keep these and similar liquids away from
your fireplace.
5.2.2. OPTIMUM USE VALUES
Primary air volume and chimney flue draught must be adjusted to levels
that
prevent boiler water temperature from exceeding 85
C
.
Maximum quantity of fuel that can be accommodated in the firebox
:
6 kg for Central 20-25 kW,
8 kg for Central 30-35 kW.